Beta models DSP 206 and FIR DSP 408 (without the FIR filters), read-only until allowed
Never tested on real hardware, so they are only selectable by hand and send no changes until the user has compared the shown values with the DSP. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
0a1f282c63
commit
86ee492ec3
11 files changed
+121
-21
No files matched your search
@@ -109,6 +109,10 @@ and the DSP's own mirroring inside groups, limiter-active bit mask, preset impor
|
||||
|
||||
Not verified yet – ask for a log (`python server.py -v`) from real hardware before changing protocol code here:
|
||||
|
||||
* **Beta models** `206` and `408fir` – never seen on real hardware, same protocol and memory layout are only assumed
|
||||
(also the USB ID). Never auto-detected (`detect_model`, a FIR device must not pass as a 408). `Device.read_only` holds
|
||||
back every write (`P.READ_COMMANDS`, `BETA_READ_ACTIONS`) until the user allows changes (`beta_write`). The FIR
|
||||
filters are deliberately not implemented; ask testers for a preset export (it holds the raw image) and a log first.
|
||||
* **DSP 408 on real hardware** (layout and frames match published captures, limiter bits for Out 5–8 assumed)
|
||||
* USB on Windows and Linux against a real DSP (only tested against a fake HID device)
|
||||
* Where the PEQ bypass flag lives in the memory image; format of the set-command acknowledgement; where the number
|
||||
|
||||
Reference in new issue
Block a user